World-Class Technical Infrastructure

World-Class Technical Infrastructure

The Lomé Data Center has a highly resilient, redundant, and secure infrastructure to ensure the continuity of your critical services 24/7/365.

Key Technical Advantages

We provide a secure and redundant environment for your equipment.

N+1 redundancy

Redundant power supply with generators and uninterruptible power supplies for maximum availability

24/7 air conditioning

Redundant cooling system maintaining an optimal temperature at all times Redundant cooling system

Enhanced Security

Biometric access control, continuous surveillance, and multi-layer perimeter protection

Fire Protection

Early detection systems and automatic extinguishing using inert gas without damage to equipment

Monitoring 24/7

Continuous monitoring of all systems with real-time alerts and response team

High Availability

Redundant architecture guaranteeing 99.99% uptime for your critical applications

Seismic Construction

Building designed to withstand extreme environmental conditions.

Multiple Connectivity

Access to multiple telecom operators with redundant routes to international destinations

Electric power
Power Supply

Electric power

The Lomé Data Center benefits from an N+1 redundant electrical architecture guaranteeing maximum energy availability for your critical infrastructure.
  • Dual electrical supply from the national grid with automatic switching
  • Emergency diesel generators with automatic start-up (N+1 capacity)
  • Modular redundant uninterruptible power supplies (UPS) ensuring a seamless transition
  • Fuel tanks providing several days of autonomy
  • Secure power distribution with intelligent rack PDUs
Air conditioning
Cooling

Air conditioning

Our redundant precision air conditioning system maintains optimal environmental conditions 24/7, which are essential for the proper functioning of your equipment.
  • N+1 redundant cooling units with temperature and humidity control
  • Hot aisles/cold aisles optimizing energy efficiency
  • Real-time temperature and humidity monitoring system
  • Water leak detection under raised floors with automatic alerts
  • Regular preventive maintenance ensuring continuous performance
Fire Protection
Fire Safety

Fire Protection

The LDC features a multi-layered fire protection system designed for early detection and rapid extinguishing, without damaging your critical equipment.
  • VESDA (Very Early Smoke Detection Apparatus) aspirating early detection system
  • Residue-free inert gas extinguishing system (FM-200 or equivalent)
  • Fire compartmentalization isolating critical areas
  • Multiple emergency exits with illuminated signage
  • Regular testing and inspections in accordance with international standards
Building
Physical Infrastructure

Building

The Lomé Data Center building was designed and built to the highest standards to house critical infrastructure with a high level of resilience.
  • Reinforced earthquake-resistant structure withstanding extreme conditions
  • Raised access floor for cabling and air distribution
  • False ceiling optimizing air circulation and lighting
  • Protection against water infiltration and moisture
  • Dedicated rooms for technical equipment (batteries, generators, air conditioning)
Safety
Access Control

Safety

The physical security of the LDC is based on a multi-layered access control system ensuring that only authorized persons can access sensitive areas.
  • Secure perimeter with fencing and protective barriers
  • Accueil et contrôle d'identité pour tous les visiteurs
  • Reception and identity check for all visitors
  • Security airlock (mantrap) at the entrance to the server rooms
  • Complete access traceability with detailed audit logs
Monitoring
Monitoring and Surveillance

Monitoring

The LDC has a 24/7/365 operational supervision center that continuously monitors all technical and security systems. The LDC has a 24/7/365 operational supervision center
  • HD video surveillance covering 100% of the perimeter and critical areas
  • Video recordings stored for a minimum of 90 days
  • Supervision center (NOC/SOC) with on-call teams
  • Real-time monitoring of all parameters (energy, air conditioning, security)
  • Automatic alerts with escalation and rapid response